AC – Accessories/Attachments

Y*00, Spacer Attachment

Y*00, Spacer Attachment

The Y*00 spacer is a more compact version of modular spacer that creates a shorter overall length to an F.R.L. assembly.  All components are retained in the spacer to simplify assembly.

  • New Style compact spacer with bracket reduces assembly space
  • Easy maintenance
  • Attaches FRL's with tightening of screws
  • O-ring prevents leakage

Y**, Spacer Assembly, AC Spare Parts

Y**, Spacer Assembly, AC Spare Parts

SMC’s legacy series of modular spacer assemblies, the Y*0spacer’s rugged design remains popular with many users.  These spacers are available simply asconnectors or with either L or T mounting brackets.

  • Spacer Assembly - old style
    see Y*10 and Y*00 - New Style
  • Easy maintenance
  • Attaches FRL's with tightening of screws
  • O-ring prevents leakage
  • Available in "T" type interface to diverge the flow of air

VHS20-50, 3 Port Residual Pressure Relief Valve, Modular

VHS20-50, 3 Port Residual Pressure Relief Valve, Modular

The VHS series provides a convenient means of isolating supplied pressure in a pneumatic system and exhausting downstream pressure for maintenance purposes.  The units can be locked in the exhaust position and can be an integral part of an energy isolation system.  Air flow direction is easily identified by handle orientation and labeling.  They can be used alone or can be conveniently connected to an F.R.L. assembly using modular spacers.  The current VHS series is no longer being produced and is subject to available quantities only.  Please utilize the new white VHS models for new designs.

  • Pressure relief, 3 port valve
  • Accessory for AC series
  • Body sizes: 1/8, 3/8, 1/2, 3/4
  • Port sizes: 1/8, 1/4, 3/8, 1/2, 3/4, 1
  • Thread types: Rc, NPT, G

VHS20-40, Residual Pressure Relief Valve, Modular, Epoxy Coated

VHS20-40, Residual Pressure Relief Valve, Modular, Epoxy Coated

The VHS series provides a convenient means of isolating supplied pressure in a pneumatic system and exhausting downstream pressure for maintenance purposes. The units can be locked in the exhaust position and can be an integral part of an energy isolation system. Air flow direction is easily identified by handle orientation and labeling.  The epoxy coated version provides an economical alternative for extended life in aggressive or washdown environments.  The current VHS series is no longer being produced and is subject to available quantities only.  Please utilize the new white VHS models for new designs.

  • Epoxy resin coating & stainless hardware for enhanced protection in corrosive manufacturing environments
  • Port sizes: 1/4, 3/8, 1/2
  • NPT threads

Y*10, T Type Spacer Attachment

Y*10, T Type Spacer Attachment

T-type interface spacers enable access of air at intermediate points in the F.R.L. assembly, such as filtered air prior to a lubricator or full line pressure prior to regulation. The current Y*10 series is no longer being produced and is subject to available quantities only. Please use the Y*10-A series of interfaces for new designs.

  • New Style T type spacer
  • Facilitates the redirection of air flow
  • Easy maintenance
  • Port size: M5 x 0.8, 1/8, 1/4, 3/8, 1/2

Y*4, Cross Spacer, AC Spare Parts

Y*4, Cross Spacer, AC Spare Parts

Cross spacers provide 4 access points to air at an intermediate point in the F.R.L. assembly such as filtered air prior to a lubricator or full line pressure prior to regulation.  The current Y*4 series is no longer being produced and is subject to available quantities only.  Please use the Y*4-A series of crosses for new designs.

 

  • Easy maintenance
  • Attaches with SMC's standard interface
  • Diverge piping in all directions

AKM**00, Check, AC Spare Parts, Metric

AKM**00, Check, AC Spare Parts, Metric

Modular check valves are primarily used immediately upstream of lubricators to prevent backflow of oil when the system is depressurized.  The current AKM series is no longer being produced and is subject to available quantities only.  Please utilize the AKM-A series of check valves for new designs.

  • Easy maintenance
  • Prevents reverse flow of lubricant oil from lubricator
  • Diverging port available in 1/8, 1/4, and 3/8

E*0, Piping Adapter Assembly, AC Spare Parts

E*0, Piping Adapter Assembly, AC Spare Parts

E*0 series piping adapters facilitate the removal of an F.R.L. assembly for maintenance purposes.  The threaded connection is made to the piping adapter which is then modularly connected to the F.R.L.  They can also allow an F.R.L. assembly to be adapted to a different line size than provided by the F.R.L. itself.  The current E*0 series is no longer being produced and is subject to available quantities only.  Please utilize the E*00-A series of piping adapters for new designs.

  • Piping adapter assembly - old style
    see E*00 - New Style
  • Easy maintenance
  • Detach equipment without removing piping
  • Assembles to FRL's by simply tightening screws
  • Available with a "L" and "T" type bracket

E*00, Piping Adaptor Attachment

E*00, Piping Adaptor Attachment

E*00 series piping adapters facilitate the removal of an F.R.L. assembly for maintenance purposes.  The threaded connection is made to the piping adapter which is then modularly connected to the F.R.L.  They can also allow an F.R.L. assembly to be adapted to a different line size than provided by the F.R.L. itself.  The current E*00 series is subject to a pending discontinuation.  Please utilize the E*00-A series of piping adapters for new designs, particularly if long term utilization is required.

  • New Style piping adapter attachment
  • Easy maintenance
  • Detach equipment without removing piping
  • Assembles to FRL's by simply tightening screws
  • Available with "T" type bracket

E210/310/410, Modular Adapter

E210/310/410, Modular Adapter

E*10 modular adaptors provide the ability to convert a threaded port to a modular connection for attachment to an F.R.L. assembly.  These can be used to connect valves, mix sizes in an F.R.L. assembly or position regulators at non-vertical angles.

  • Modular Adapter
  • Easy connection to existing products
  • Flexible mounting
  • Reduced space/piping maintenance cost

E210-P/310-P/410-P, Modular Plug

E210-P/310-P/410-P, Modular Plug

Modular plugs are used to cap off the end of a modular run for connection at a future time.

  • Modular Plug
  • Easy connection to existing products
  • Flexible mounting
  • Reduced space/piping maintenance cost

E300P/400P, L-Shaped Piping Adapter

E300P/400P, L-Shaped Piping Adapter

A rugged elbow for directing flow at 90o from the normal F.R.L. inlet/outlet.  These are designed to be either hard piped or connected via an E*10 piping adapter.

  • L-Shaped Piping Adapter
  • Easy connection to existing products
  • Flexible mounting
  • Reduced space/piping maintenance cost