- SMC Home
- Products
- Directional Control Valves
- Valve Manifold Configurator
- VQC Valve Manifold Configurator
- 5000 Series
VQC Valve Manifold Configurator – 5000 Series
The VQC series has five standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of three of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.

VQC5000 Manifold/Valve Assembly with EX600
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- Base mount EX600 type plug-in manifold for VQC5000 valves
- Protective enclosure conforms to IP67 for protection from
dust and moisture - DeviceNet™, PROFIBUS DP and CC-Link, EtherNet/IP™, EtherCAT fieldbus protocols
- Maximum 12 stations available as standard

VQC5000 Manifold/Valve Assembly with D-sub
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mount, plug-in valves
- Conforms to IP40
- D-sub connector reduces labor while minimizing wiring and saving space
- 25 pin D-sub connector that conforms to MIL standards
- 1 to 12 stations available as standard

VQC5000 Manifold/Valve Assembly with EX260
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- Base mount EX260 type plug-in manifold for VQC5000 valves
- DeviceNet™, PROFIBUS DP, CC-Link, Ether CAT and PROFINET fieldbus protocols
- Maximum 12 stations available as standard

VQC5000 Manifold/Valve Assembly with Lead Wire
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mount, plug-in valves
- Conforms to IP67 for protection from dust and moisture
- Direct electrical entry type
- 1 ~ 12 stations available as standard

VQC5000 Manifold/Valve Assembly with Circular Connector
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mount, plug-in valves
- Conforms to IP67 for protection from dust and moisture
- Multi-connector kit
- 1 ~ 12 stations available as standard

VQC5000 Manifold/Valve Assembly with Flat Ribbon Cable
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mount, plug-in valves
- Conforms to IP40
- Flat ribbon cable reduces labor while minimizing wiring and saving space
- Flat ribbon cable connectors (26P and 20P) conform to MIL standards
- 1 to 12 stations available as standard

VQC5000 Manifold/Valve Assembly with EX500
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
For VQC5000 base mount, plug-in valves
VQC5000 Manifold/Valve Assembly with EX250
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mounted, plug-in valves
- Protective enclosure conforms to IP67 for protection from dust and moisture
- I/O serial transmission kit reduces connection work, minimizes wiring and saves space
- Replaceable one-touch fittings
- 1 to 12 stations available as standard

VQC5000 Manifold/Valve Assembly with EX126
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- Manifold with EX126 SI unit
- Easy installation and removal of SI unit
- Conforms to CE marking
- IP67 enclosure
- Maximum 8 stations as standard
- Corresponding to CC-Link Ver.1.10

VQC5000 Manifold/Valve Assembly with Terminal Block Box
The VQC series has six standard wiring packages bringing a world of ease to wiring and maintenance work, while the protective enclosures of four of them conform to IP67 standards for protection from dust and moisture. The use of multi-pin connectors to replace wiring inside manifold blocks provides flexibility when adding stations or changing manifold configuration. The VQC series has outstanding response times and long life.
- For VQC5000 base mount, plug-in valves
- Conforms to IP67 for protection from dust and moisture
- Terminals are concentrated in compact clusters within the terminal block box
- G3/4 electrical entry allows connection of conduit fittings
- 1 to 10 stations available as standard
Products
- Actuators
-
Directional Control Valves
- Directional Control Valves Overview
- Solenoid Valves - 4 & 5 Port
- Solenoid Valves - 3 Port
- Solenoid Valves - Direct Operated
- Industrial Communication
- Air Operated Valves
- Mechanical & Hand Operated Valves
- Safety Pressure Relief Valves
- Solenoid Valves - ISO
- Clean Room Products
- Valve Manifold Configurator
- Airline Equipment
- Air Dryers & Main Line Filters
- Connectors
- Vacuum Products
- Industrial Communication
- Sensors & Switches
- Fluid Process
- Static Control
- Electric Actuators
- Chillers
- Process Gas Equipment
- High Vacuum
- Chemical Handling Equipment
- Secondary Battery